FIRST equipment on the market with IOT 4.0 TECHNOLOGY
HYDROSMART TECHNICAL SPECIFICATIONS
ANTIVANDALIC - ARMORED
COMPLIANCE WITH IP65 STANDARDS.
In all the components of the equipment, screen, casing, connectors, air dissipators, etc.
EASY INSTALLATION
Allows connection without tools
FIRST equipment on the market with IOT 4.0 TECHNOLOGY
Access from any electronic device on the market
- Multi-screen connection. Supports HDMI connection. Connection of several screens to the same Central Unit for Hotels, City Halls, etc. for the presentation of information to the user. The customer defines the parameters to be displayed.
- Full functionality of the Central Unit without display. Access to information from a URL from any device as if we were in front of the computer.
- If the screen or the server suffers an incident, the service is not interrupted. The only equipment on the market with this possibility.
- Acts as a server. All data are recorded and stored in the equipment. We do not depend on external servers.
- The Server contains a MySQL Database. The customer will be able to view the stored data or export it to any type of device or external cloud.
- Remote connection via IP. This IP address will only be known to the user.
- The customer is independent and owner of his data.
- Security with MAC filtering. In this way, the router only lets through incoming connections that the user authorizes.
- Security by serial number associated with a separate password that will be given to the Master user in an envelope for safekeeping.
- 100% operational remote maneuverability. The remote maneuverability of the equipment is as if we were in front of the equipment.
- Connections with other devices. Modbus, cambus, P serial, RS485, etc.
HYDROSMART CONNECTIONS
Each team is capable of managing
up to 39 analog and digital connections
ILLIMITED CONNECTIONS
A Master unit can have as many slaves as you want
Ph, Rx and CL probe connectors of type SNA shielded.
Ph, Rx and CL probe connectors of type SNA shielded.
The CL probe can be potentiostatic or amperometric.
Unlimited number of connections possible
of probes via Ethernet or wifi.
Remote probe calibration.
We can calibrate the probes remotely,
we just need the help of someone who can introduce
the probes in their corresponding tampons.
OXIDATION CONTROL OUTPUT
AUXILIARY DOSING PUMP OUTLET
INLET PRESSURE SWITCH FILTER
AUXILIARY CARAFE LEVEL INPUT
PH CYLINDER LEVEL INLET
NTU-TURBIDITY PROBE
PH DOSING PUMP OUTPUT
REDOX DOSING PUMP OUTPUT
CHLORINE DOSING PUMP OUTPUT
FILTRATION PUMP CONTROL OUTLET
PUMP DRIVE CONTROL OUTPUT
GENERAL FAULT OUTPUT
SALT CONTROL OUTPUT
LIGHT CONTROL OUTPUT
AIR CONDITIONING CONTROL OUTPUT
FLOW DETECTOR INPUT
CHLORINE CYLINDER LEVEL INPUT
TDS PROBE
TEMPERATURE PROBE
I2C PORT-SDA-SCL- COMMUNICATION
RS232 TTL
PORT-RX-TX - COMMUNICATION
HYDROSMART ELECTRODES
Titanium - Ruthenium - Iridium - PLATINUM
The composition of HidroSmart electrodes is Titanium-Ruthenium and Iridium, we also have electrodes with a final platinum bath, to work in drinking water systems, thus anticipating the European regulation on the use of titanium in drinking water.
All our electrodes are intended to work in low conductivity water, so it is not necessary to add salt to the water except in salt electrolysis systems or if the conductivity of the water is lower than 400 ppm.
The disinfection chamber is placed in line with the return pipe, the benefits of these features are as follows:
Easier installation, especially in small treatment plants.
The use of elbows is not necessary, with the consequent economic savings.
Assumes minimal load loss.
The length of the disinfection chamber is 450 mm and its different diameters are 75 mm, 90 mm and 110 mm.
The degree of power delivery is optimal as the water flow passes through all the sheets that make up the electrode, the electrode contact surface with the water flow being 100%.
The scaling of the disinfection capacity in m3 of the electrodes varies according to the number of Titanium plates, being currently able to disinfect the following volumes of water with a single disinfection chamber, 35 m3, 70 m3, 150 m3, 275 m3 and 400 m3.
The connection terminals to the electrode always guarantee a good contact without spark, as they have a 30 Ampere copper terminal and are fixed with a screw. In addition, once the connection maneuver has been carried out, it is watertight and insulated with heat shrink.
The connection cable is 10 mm Red and Black section and 1.5 meters long, approved for direct current systems to minimize losses.
It is connected to the power unit by means of a TE Connectivity plug , approved for use with DC power units up to 30 amps.
The opening of the chamber is extremely simple by means of clamps and Allen screws. Once opened, the electrode comes completely out of the chamber by pulling it out for maintenance.
The operating pressure of the chamber is 5 bar and the maximum pressure is 10 bar.