CONTROL, MEASUREMENT AND
AUTOMATION
SYSTEM OF DOSAGE AUTOMATIC
DOSING PUMPS
We have high performance dosing pumps for the control, measurement and automation of chemical elements.
A wide range of Dosing Pumps, both Peristaltic and Electromagnetic. Easy to use and with all the functions you may need. Display of the Rx or Ph value of the pool, overdose alarm, digital display, etc. We will use our dosing pumps in disinfection, spas and industrial projects and wherever we want to continue with the use of Sodium Hypochlorite. These pumps are also present in the Hydrolysis and Salt Chlorination technologies, as they are in charge of their control, measurement and automation.
Peristaltic Dosing Pumps
MP2- SPEEDY Ph / Redox
Peristaltic pump with integrated pH/Redox/ORP instrument
Suitable for dispensing acidic products
Set point programming between 6.0 and 8.0 pH
Set point programming between 300 to 900 mv. Redox
Semi-automatic single-value calibration of pH 7.01
Semi-automatic single-value calibration of 468 mv. Redox
Visualization of redox on display
Dosing proportional to the defined set point
ON / OFF function
PP box loaded with 30% talc
Polycarbonate front panel
IP 55 protection
– SCHUKO plug
– ON / OFF switch
MP2- HT Ph / Redox
Digital peristaltic pump with built-in PH/REDOX and temperature control instrumentation
Choice of the type of control (PHoREDOX) by software
Suitable for dosing acidic or basic / oxidizing or reducing products
3 possible types of operation: Manual, ON/OFF, Proportional
Manual function: constant dosing
ON/OFF function: constant dosing with programmable activation
Proportional function: dosing proportional to the set point, fully programmable proportioning range
Proportioning proportioning by varying motor rotation speed
Menu selection in 4 languages: Italian, English, French or Spanish.
Instantaneous display of the flow rate in %.
Instantaneous display of PH/REDOX value and temperature
Programmable password
Programmable temporary over-dosing alarm
Programmable start delay
Dosing stop with STAND-BY function
Suction button for quick installation
Resetting the default parameters
16 x 2 backlit digital display
Status and dosage alarm LED
Standard power supply 90 ÷ 250 Vac 50-60 Hz
Reinforced PP case
Polycarbonate glass with quick connect/disconnect system
PBT roll holder for 2 rolls
Increased motor life and better performance under pressure thanks to a bearing for roll holder rotation
IP55 protection
Easy programming and minimal maintenance
100 % Made in Italy
In compliance with EC regulations
SCHUKO plug
– Level probe signal input
– Flow Sensor Input
– ON / OFF switch
MP2- HT CHLORINE
Digital peristaltic pump with built-in PH/REDOX and temperature control instrumentation
Choice of the type of control (PHoREDOX) by software
Suitable for dosing acidic or basic / oxidizing or reducing products
3 possible types of operation: Manual, ON/OFF, Proportional
Manual function: constant dosing
ON/OFF function: constant dosing with programmable activation
Proportional function: dosing proportional to the set point, fully programmable proportioning range
Proportioning proportioning by varying motor rotation speed
Menu selection in 4 languages: Italian, English, French or Spanish.
Instantaneous display of the flow rate in %.
Instantaneous display of PH/REDOX value and temperature
Programmable password
Programmable temporary over-dosing alarm
Programmable start delay
Dosing stop with STAND-BY function
Suction button for quick installation
Resetting the default parameters
16 x 2 backlit digital display
Status and dosage alarm LED
Standard power supply 90 ÷ 250 Vac 50-60 Hz
Reinforced PP case
Polycarbonate glass with quick connect/disconnect system
PBT roll holder for 2 rolls
Increased motor life and better performance under pressure thanks to a bearing for roll holder rotation
IP55 protection
Easy programming and minimal maintenance
100 % Made in Italy
In compliance with EC regulations
SCHUKO plug
– Level probe signal input
– Flow Sensor Input
– ON / OFF switch
P PRO PH / REDOX
Digital peristaltic pump with built-in PH/REDOX instrument
Choice of pH or mV (ORP) control type adjustable by software
3 modes of operation: Constant ON / OFF, proportional
Menù in 4 languages: English, Italian, French or Spanish
Alarm in case of overdose programmable in duration
Programmable start delay
8 x 2 backlit digital display
Alarm LED Status and programming
Glass-reinforced PP case for adequate chemical resistance
IP 65 protection
Input power 8 Watts
PVC Suction Pipe 4×6
Distribution Pipe PE 4×6
BNC Probe Attack
Delrin rollers
SCHUKO plug
– Level probe signal input
– Flow Sensor Input
– ON / OFF switch
MP DUAL PH REG REDOX
Dual system with pH, redox and T° temperature instrumentation
Indication of flow rate in % istantanea
3 possible types of operation: constant, ON / OFF, proportional
Menù in 4 languages: Italian, English, French and Spanish
Programmable password
Programmable start delay
Programmable overdose alarm time
Alarm relay ( CLEAN CONTACT)
Restore default parameters
Role of pH stability
Stop dose with function STAND_BY
Measurement over and under range signal
Digital LCD backlit display
Glass-filled PP casing for adequate chemical resistance
IP 65 protection
Indication of flow rate in % istantanea
Standard power supply 230vac 50-60 Hz 1A
Delrin rollers.
Santoprene tubing.
PVC Suction Pipe 4 x 6
PE delivery pipe 4 x 6
BNC Probe Attack
-Level probe signal input
– Flow Sensor Input
– ON / OFF switch
COMPLETE MP2- SPEEDY FAMILY PANEL. Ph / Redox
Electrically wired thermoformed panel.
Pump with integrated ORP/Redox instrument with set point adjustment.
Pump with integrated PH instrument with set point adjustment.
Defluorocarriers with 50 micron pre-filter.
Sample tap.
Simplified programming.
Self-calibration of a buffer solution.
Buffer solutions Ph 7 and 468 mV
SCHUKO plug
Ph and Redox electrode, epoxy body, 1 m long cable.
Standard power supply 230 Vac
100 % Made in Italy
Conforms to EC regulations
– Level probe signal input
– Flow Sensor Input
– ON / OFF switch
Electromagnetic dosing pumps
ME3- C
Electromagnetic pump
Adjustable flow rate in %.
Programmable start delay
Three-digit display
Reinforced PP case
IP 65 protection
100% Made in Italy
Conforms to EC regulations
Standard power supply 230 Vac
ON / OFF switch
Input for level sensor
PVDF body recommended for
the dosing of oxidizing products
– SCHUKO plug
– ON / OFF switch
Technical Characteristics
ME1 S PH / REDOX
Digital electromagnetic pump with proportional dosing.
Integrated Redox or Ph instrument
Instant display of the Rx or Ph value of the pool.
Easy to use keypad with two buttons, one for semi-automatic calibration and one for programming.
CAL rate for automatic calibration of the Rx probe at a single point 468 mV
CAL rate for Automatic Ph probe calibration at a single point of Ph 7.0
PH: SET rate for set point programming between 6.0 Ph and 8.0 Ph.
Redox: SET button for set point programming between 300 and 800 mV.
Automatic recognition of the ORP or Ph probe.
Overdose alarm integrated in the software to avoid chemical overdose.
Suitable for dispensing Ph + and Ph – (basic acids) or Chlorine Oxidizers.
Easy and minimal maintenance
PP box loaded with 30% talc
Polycarbonate front panel
Digital segment display.
Pump body with manual drain
IP 65 protection
Standard power supply 230vac
Conforms to EC regulations.
100 % Made in Italy
Pump body: PP.
PVC Suction Pipe 4×6
Delivery pipe PE 4×6
Valve Body PP 4×6
PP Gaskets
-ON/OFF switch
-It is advisable to order PVDF / PTFE pump body for use with concentrated Sodium Hypochlorite or other strong Oxidizers.
Technical Characteristics
ME3 PH REDOX / CL2
MULTIFUNCTION digital electromagnetic pump. According to Model.
Digital electromagnetic pump MULTIFUNCTION proportional to signal 0/4-20 mA
Digital electromagnetic pump for meter reading pulses. According to Model.
Possibilities of constant and proportional operation. According to model
Possibility of counter work, 0/4-20 mA and constant
Selection of the function 1/n, 1xn, 1xn(M) with memory and p.p.m. mode.
Menù in 4 languages: Italian, English, French and Spanish
Programmable start delay
Digital display 8 x 2 backlit
Status and programming alarm LED
Glass-filled PP casing for adequate chemical resistance
IP 65 protection
Measurement over and under range signal
Indication of flow rate in % istantanea
MADE IN ITALY
100 % tested before shipment
Conforms to EC regulations
Standard power supply 230vac
Pyrex spheres
PTFE diaphragm
Viton seals
PVC Suction Pipe 4×6
Pipe delivery PE 4×6
-Level probe signal input
-Input for flow sensor
-ON/OFF switch
PVDF / PTFE pump body recommended when using concentrated SODIUM IPOCLORITE or strong oxidants.
Technical Characteristics
ME1- I
MULTIFUNCTION digital electromagnetic pump. According to Model.
Digital electromagnetic pump MULTIFUNCTION proportional to signal 0/4-20 mA
Digital electromagnetic pump for meter reading pulses. According to Model.
Possibilities of constant and proportional operation. According to model
Possibility of counter work, 0/4-20 mA and constant
Selection of the function 1/n, 1xn, 1xn(M) with memory and p.p.m. mode.
Menù in 4 languages: Italian, English, French and Spanish
Programmable start delay
Digital display 8 x 2 backlit
Status and programming alarm LED
Glass-filled PP casing for adequate chemical resistance
IP 65 protection
Measurement over and under range signal
Indication of flow rate in % istantanea
MADE IN ITALY
100 % tested before shipment
Conforms to EC regulations
Standard power supply 230vac
Pyrex spheres
PTFE diaphragm
Viton seals
PVC Suction Pipe 4×6
Pipe delivery PE 4×6
-Level probe signal input
-Input for flow sensor
-ON/OFF switch
PVDF / PTFE pump body recommended when using concentrated SODIUM IPOCLORITE or strong oxidants.
Technical Characteristics
MP DUAL PANEL
Ph / Redox
pH stability function to avoid chlorine dosing at pH values different from the set point
Thermoformed panel electrically wired IP 65
Alarm relay ( CLEAN CONTACT )
MP DUAL pH/redox dosing system
Stopping dosing with the STAND_BY function
with integrated instrument with instant display
of pH and redox in two decimal numbers and of the temperature °C
Backlit LCD display
Resetting the default parameters
50micron filter with washable net inside the deflux probe holder model PRO-H2C
4 x 6 or 8 x 12 water inlet
Signal over / under range of the measurement
Flow sensor for dosing to stop when the instrument is not in operation
Overdose alarm to avoid excess chemicals in the tank
Setting the start-up delay
Delrin rollers
Configuration of a password protection
Consumption 8 Watts
Instantaneous flow rate signal indicated in %.
BNC Probe Attack
3 possible types of operation: constant, ON / OFF, proportional
Menu in ITALIAN, ENGLISH, FRENCH, SPANISH, SPANISH
Predisposition to flow sensor
Predisposition to level probe
Probe predisposition
temperature